SENSORS

Toxic and combustible sensors, the Air 2000 Series, CO220 Series and Tox-ANA series of sensors provide a 4 to 20 mA or 0-10 vdc output signal. They are designed for integration with the Tox-4ANA and ToxControl controllers to provide you with a complete gas monitoring system.

Also, if desired the sensors may be used to be interfaced directly with other DDC or energy management systems.


-Air 2000 Series-
[Data Sheet] [Guide Specification]
Non dispersive infrared carbon dioxide (CO2) sensor for monitoring indoor air quality. Range of 0-2000 ppm. Other ranges available.

-Air 3000 Series-
[Data Sheet] [Guide Specification]
Sensor for monitoring indoor air quality.

-CO220 Series-
[Data Sheet] [Guide Specification]
Non dispersive infrared carbon dioxide (CO2) sensor for monitoring diesel engine emissions. Range of 0-2000 ppm.

-Tox-CO/ANA-
[Data Sheet] [Guide Specification]
Carbon Monoxide sensor utilizing metal semi-conductor technology. Standard range 0-400 ppm. Other ranges available.

-ToxCO-ANA/EC-
[Data Sheet] [Guide Specification]
Carbon Monoxide sensor utilizing electro chemical technology. Range of 0 - 500 ppm.

-Tox-CL2/ANA-
[Data Sheet] [Guide Specification]
Chlorine sensor utilizing eletro chemical technology. Range of 0-10 ppm.

-Tox-Comb/ANA-
[Data Sheet] [Guide Specification]
Combustible (i.e. methane, propane, natural gas, etc.) sensors utilizing catalytical bead technology. Range of 0-100% LEL (lower explosive level).

-Tox-ETO/ANA-
[Data Sheet] [Guide Specification]
Ethylene Oxide sensor utilizing electro chemical technology. Range of 0-20 ppm.

-Tox-H2/ANA-
[Data Sheet] [Guide Specification]
Hydrogen toxic gas sensor utilizing electro chemical technology. Range of 0-1000 ppm. Note: For monitoring combustible hydrogen from battery charging applications, see Model Tox-Comb/ANA

-Tox-HCI/ANA-
[Data Sheet] [Guide Specification]
Hydrogen chloride sensor utilizing electro chemical technology. Range of 0-20 ppm.

-Tox-HCN/ANA-
[Data Sheet] [Guide Specification]
Hydrogen cyanide sensor utilizing electro chemical technology. Range of 0-20 ppm.

-Tox-H2S/ANA-
[Data Sheet] [Guide Specification]
Hydrogen sulfide sensor utilizing electro chemical technology. Range of 0-100 ppm.

-Tox-NH3/ANA-
[Data Sheet] [Guide Specification]
Ammonia sensor utilizing electro chemical technology. Range of 0-50 ppm.

-Tox-NH3/SS36-
[Data Sheet] [Guide Specification]
Ammonia sensor utilizing solid state metal oxide semiconductor technology. Range of 20-500 ppm.

-Tox-NO/ANA-
[Data Sheet] [Guide Specification]
Nitric oxide sensor utilizing electro chemical technology. Range of 0-20 ppm.

-Tox-NO2/ANA-
[Data Sheet] [Guide Specification]
Nitrogen dioxide sensor utilizing electro chemical technology.. Range of 0-20 ppm.

-Tox-O2/ANA & Tox-O2/DIG-
[Data Sheet] [Guide Specification]
Oxygen sensor utilizing electro chemical battery cell technology. Range 0-25% oxygen.

-Tox-Refrig/ANA-
[Data Sheet] [Guide Specification]
Refrigerant sensor utilizing solid state metal semiconductor technology. Range 0-500 ppm.

-Tox-SO2/ANA-
[Data Sheet] [Guide Specification]
Sulfur dioxide sensor utilizing electro chemical technology. Range of 0-100 ppm.

-Tox-4100 Series-
[Data Sheet]
Hydrocarbon sensor utilizing metal semiconductor technology. Range of 20-500 ppm or 50-5000 ppm.